Development and evaluation of a novel force myography (FMG) based human-machine interface for transradial prosthetics: A comparative study with electromyography (EMG) techniques

  • Azam Jan Department of Mechatronics Engineering, University of Engineering and Technology (UET), Peshawar, Pakistan
  • Ihtisham Ul Haq Department of Computer Science, Modelling, Electronics and Systems (DIMES), University of Calabria, Rende, 87036, CS, Italy
  • Muhammad Anas Department of Electrical and Electronic Engineering, Swinburne University of Technology, Hawthorn campus Australia
  • Ghassan Husnain Department of Computer Science, Iqra National University, Peshawar, Pakistan
  • Waqas Ahmad Department of Computer Science, Iqra National University, Peshawar, Pakistan

Abstract

Human-Machine Interfaces (HMIs) must bridge human skills with machine control, notably in active prosthesis. Electromyography (EMG) is the most popular prosthesis actuation method. However, researchers need new HMIs for active prosthesis development. This research introduces Forcemyography (FMG) based HMI using force- sensitive resistors (FSRs) to capture myoelectric data. A particularly constructed case with two integral parts—an internal and an exterior component—is FMG. This FMG enclosure adapts effortlessly to the user's limb and shape for best performance and comfort. FMG and sEMG were compared in the  experimental evaluation. Stability, forecast accuracy, hair and sweat resistance, wearability, and cost-effectiveness were examined. FMG signals outperformed sEMG signals in this comprehensive examination. FMG outperformed sEMG in stability and prediction accuracy. FMG produced outstanding results right from capture without post-processing, a unique advantage. The specialised enclosure protected FSRs from outside interference and delivered precise signals. The Forcemyography (FMG)-based HMI is a breakthrough in active prosthesis technology. Its versatility, consistent signal acquisition, and user-centric design promise improved human-machine interactions. FMG leads the way to smooth, intuitive, and efficient humanmachine interface.

Published
Oct 1, 2024
How to Cite
JAN, Azam et al. Development and evaluation of a novel force myography (FMG) based human-machine interface for transradial prosthetics: A comparative study with electromyography (EMG) techniques. Mehran University Research Journal of Engineering and Technology, [S.l.], v. 43, n. 4, p. 55-62, oct. 2024. ISSN 2413-7219. Available at: <https://publications.muet.edu.pk/index.php/muetrj/article/view/2948>. Date accessed: 21 nov. 2024. doi: http://dx.doi.org/10.22581/muet1982.2948.
Section
Articles
This is an open Access Article published by Mehran University of Engineering and Technolgy, Jamshoro under CCBY 4.0 International License